Industrial Electronic Engineers, Inc.
SIZE
A
CODE IDENT NO.
05464
SLB325-X4X0
Van Nuys, California
SCALE N/A
REV
B
SHEET 18
05/23/02
4.5
Dedicated Hardware Lines
Not available.
4.6
Serial Data and Self-test
Serial characters are received with data formatted as a 10-bit word. The command set is structured to allow
transmission of 8 data bits. The data rate is fixed at 9600 baud. The level is EIA-232C.
(EIA-232) (LSB) (MSB)
+15 TO +3V
-15 TO -3V
b0
b1
b2
b3
b4
b5
b6
b7
1 START BIT 8 DATA BITS 1 STOP BITS
Self-test is a very useful feature and can be activated by sending 1F-40 (HEX). The test may be terminated by
sending 1B-40 (HEX). Characters from 20 (HEX) to F4 (HEX) will be displayed advancing through the
characters at approximately 2.0 characters per second. This self-test capability can be used to speed up
both in-field fault isolation and incoming receiving inspection.
4.7
Connector Pin Assignment
EIA-232C
J1 (RJ-45)
PIN NO.
FUNCTION
*1
SIGNAL GROUND
2,7
11-29 VDC
3
TRANSMIT DATA (OUTPUT)
4
DATA SET READY (INPUT)
5
DATA TERMINAL READY (OUTPUT)
6
RECEIVE DATA (INPUT)
*8
POWER RETURN
* Shielded cable and connector are standard.
EIA-422A
J1 (RJ-45)
PIN NO.
FUNCTION
*1
SIGNAL GROUND
2,7
11-29 VDC
3
TRANSMIT DATA (A+)
4
TRANSMIT DATA (A-)
5
RECEIVE DATA (A-)
6
RECEIVE DATA (A+)
8
POWER RETURN
* Shielded cable and connector are standard.