Industrial Electronic Engineers, Inc.
SIZE
A
CODE IDENT NO.
05464
SLB325-X4X0
Van Nuys, California
SCALE N/A
REV
B
SHEET 7
05/23/02
4.2.1
Instruction (Cont’d)
DATA (HEX)
DESCRIPTION
0E
MAKE CURSOR INDICATOR INVISIBLE (the cursor location counter continues to function
but there is no visible indicator of next character location)
0F
+ MAKE CURSOR INDICATOR VISIBLE, FLASHING BLOCK.
<10>
BOTTOM LINE DATA ENTRY WITH AUTOMATIC CARRIAGE RETURN & LINE FEED
(puts cursor a left side bottom row and data enters beginning at the left-most character
position of the bottom row, vertical scroll from bottom line after line has been filled)
<11> + NORMAL DATA ENTRY WITH AUTOMATIC CARRIAGE RETURN AND LINE FEED
(data enters beginning at the home position, vertical scroll from bottom line after line
has been filled)
<12>
OVERWRITE OF RIGHT-MOST CHARACTER ON THE PRESENT LINE/AUTOMATIC
CARRIAGE RETURN OFF
<13>
HORIZONTAL SCROLL MODE (from right to left on bottom line only, after line has been
filled)
14
RESET (go to system default settings and clear all DOWN LOAD CHARACTERS)
15
+ DISPLAY CLEAR (puts cursor at left side bottom row in Mode 10 HEX, & home in Modes
11 HEX, 12 HEX, 13 HEX and 1A HEX)
16
+ CURSOR HOME (returns cursor to upper left-most position)
17
BACKLIGHT ON
18
+ BACKLIGHT OFF (Blinks ON momentarily during power-up)
19
SET BIT 7 HIGH FOR NEXT BYTE ONLY:
19-00 TO 19-7F: Same as ASCII 80-FF
<1A>
WRAP AROUND DATA ENTRY:
(After bottom right character enters, cursor moves to home position)
1B
1B-05-49
IEE SPECIFIC RESPONSE CODE
(Sent without regard for flow control)
D,2,IEE,35964,-03 (CR) (18 BYTES)
1B-26-01-M-N
DEFINE DOWN LOAD CHARACTERS (5x8 DOT CHARACTER ONLY)
M=BYTE LOCATION TO BEGIN DOWNLOAD (20 to FF)
N=NUMBER OF CHARACTERS TO BE DOWNLOADED
EACH CHARACTER PATTERN IS 5 BYTES (See 4.4)
1B-3F-N
DELETE DOWNLOAD CHARACTER LOCATION N (N=20-FF)
1B-40
TERMINATE SELF TEST (all configurations go to default setting
and clear all DOWN LOAD CHARACTERS)