34
ACCURA9/9L INSTRUCTION MANUAL
10 Remote
Mode
ACCURA 9/9L can be controlled to dispense by the external signal.
RS232C communication, parallel communication
(
EXIT I/O
)
and foot switch can be controlled.
Each signal and control should be operated as follows:
※
Refer to 11. Input & Output Signal Interface about Input & Output signals.
Operation procedure
L C D
S C R E E N
P R O C E D U R E
1
AUTO Shot Screen
*** Auto Shot ***
Ch 00 St 00.100
Sp 100.0 Sc 000300
Cm LE VC
Show the shot screen at AUTO mode or STEADY
mode .
2
Auto Shot Remote Screen
*** Auto Shot EXT
Ch 00 St 00.100
Sp 100.0 Sc 000300
Cm LE VC
After entering the
REMOTE
key
, the condition of
remote mode will appear on upper right corner. The
controller can be controlled by means of the Foot
switch
(
FSW
)
,
EXIT I/O
(
EXT
) and RS232C
(
RS2
)
.
***** on the upper right screen means a normal
condition.
Pressing
REMOTE
key every one time, "***"
、
"FSW"
、
"EXT" and "RS2" is shown in order one
by one.
(
The left screen is on the EXIT I/O.
)
To complete the remote mode:
Enter the
REMOTE key
again.