37
ACCURA9/9L INSTRUCTION MANUAL
Communication data format
No.
byte
Description
Communication data (Head data)
Shot period
5
00.250
ʼ00250ʼ
Shot pressure
4
100
.
0
ʼ1000ʼ
Shot count
6
000100
ʼ0001000ʼ
Vacuum pressure
5
024
.
0
ʼ0240ʼ
Vacuum operation time
4
00.
30
ʼ0030ʼ
Vacuum operation OFF
time
4
00.
5
0
ʼ00
50
ʼ
Mode
1
‘0’ AUTO,’1’: STEADY
Barrel capacity
1
‘0’: 5ml. ‘1’ : 10ml
‘2’ : 30ml, ‘3’ :50ml
‘4’ : 170ml
Data(1~8) 6
‘012345’
Every data is stored the first byte as the high end. Omit a decimal point.
List of Received-command description
①
Clear count:
..
Clear shot count (current count).
Kind Item
Byte
No. Figure
1
Data length
1
0Ch
2
Command
2
ʼC
②
Stored Data
..
The data is stored at the received channel mode.
AUTO mode
STEADY mode
Kind Item
Byte No.
Figure
Item
Byte No. Figure
1
Data length
1
1Eh
Data length
1
113h
2
Command
2
ʼSEʼ
Command
2
ʼSEʼ
3
Channel
Mode
Shot period
Shot
pressure
Shot count
2
1
5
4
6
ʼ0ʼ
※
1
※
1
Channel
Mode
Shot vacuum
2
1
4
ʼ1ʼ
※
1
※
1
Omit a decimal point.