ACT-457A Panel PC
Page 39
Field
Command
End
Data RM
CR
(0x0d)
Table 3-9: Get Mifare Parameter Raw Data Format
Status (2 digits)
Block Data
END (2 digits)
OK
Access mode (1 digit) +
Block (2 digits) + Mode (1 digit)
CR,LF (0x0d,0x0a)
ER
Error Code (3 digits)
CR,LF (0x0d,0x0a)
Table 3-10: Get Mifare Parameter Response Format
3.5.5 Set RF320 Mode
The Set RF320 Mode command is to set the type of RFID card for the RFID reader to
detect. To set the type of RFID card, please follow the steps below.
Step 1:
Select
Set RF320 Mode
in the command area (
).
Step 2:
Select a RF320 mode.
1-EM12K: detect EM cards only.
2-Mifare: detect Mifare cards only.
3-EM and Mifare: detect both EM and Mifare cards.
Step 3:
Click the
Execute
button to execute the command through the selected serial
port (
). The raw data of this command shows in the Raw Data area in
the format listed in
and
Step 0:
Summary of Contents for ACT-457A
Page 9: ...ACT 457A Panel PC Page 1 Chapter 1 1 Introduction...
Page 18: ...ACT 457A Panel PC Page 10 Figure 1 9 Front Dimensions...
Page 19: ...ACT 457A Panel PC Page 11 Figure 1 10 Cutout Dimensions...
Page 20: ...ACT 457A Panel PC Page 12 Chapter 2 2 Installation...
Page 37: ...ACT 457A Panel PC Page 29 Figure 2 17 Digital I O Cable Installation...
Page 38: ...ACT 457A Panel PC Page 30 Chapter 3 3 RFID Reader...
Page 49: ...ACT 457A Panel PC Page 41 Chapter 4 4 System Maintenance...
Page 53: ...ACT 457A Panel PC Page 45 Appendix A A External Connector Pinouts...
Page 57: ...ACT 457A Panel PC Page 49 Appendix B B Terminology...
Page 61: ...ACT 457A Panel PC Page 53 Appendix C C Watchdog Timer...
Page 64: ...ACT 457A Panel PC Page 56 Appendix D D Hazardous Materials Disclosure...