AFL-517A-GM45 User Manual
Page 111
Figure 5-11: Smart Fan Setting – PWM Mode
5.4.3.3 Automatic Mode
In the Automatic Mode, the user can set the temperature that decides the fan activity. The
following value can be set (
574H
Figure 5-12
):
Fan Start (°C): the fan starts when the temperature reaches the set value
Fan Off (°C): the fan turns off when the temperature reaches the set value
Full Speed (°C): the fan runs at full speed when the temperature reaches the
set value
Start PWM Value (0~127): the initial PWM value when the fan starts
Slope (PWM Value (add/°C): the PWM value added per degree Celsius (°C)
of temperature increase when the fan start running
To set the value, double click the number and enter a new value. Click
apply
or
ok
when
finished.
Summary of Contents for AFL-517A-GM45
Page 12: ...AFL 517A GM45 User Manual Page 12 Chapter 1 1 Introduction...
Page 21: ...AFL 517A GM45 User Manual Page 21 Chapter 2 2 Installation...
Page 55: ...AFL 517A GM45 User Manual Page 55 Chapter 3 3 System Maintenance...
Page 65: ...AFL 517A GM45 User Manual Page 65 Chapter 4 4 BIOS Options...
Page 103: ...AFL 517A GM45 User Manual Page 103 Chapter 5 5 iSMM...
Page 119: ...AFL 517A GM45 User Manual Page 119 Appendix A A Safety Precautions...
Page 123: ...AFL 517A GM45 User Manual Page 123 Appendix B B BIOS Options...
Page 126: ...AFL 517A GM45 User Manual Page 126 Appendix C C Terminology...
Page 130: ...AFL 517A GM45 User Manual Page 130 Appendix D D Watchdog Timer...
Page 133: ...AFL 517A GM45 User Manual Page 133 Appendix E E Hazardous Materials Disclosure...