AFL2-17AB-H61 P a n e l P C
P a g e 120
Enabled
Enables the Fanless Temp. Overwrite control function.
Disabled
D
EFAULT
Disables the Fanless Temp. Overwrite control function.
Te m p e ra tu re Of Fa n le s s [32 C]
NOTE:
If the Temperature of Fanless is enabled, the fan will only turn on when
the Environment Temperature 1 reaches to the temperature set in the
following Temperature of Fanless option.
For safety reason, the fan will turn on automatically to cool down the
system when the CPU temperature exceeds 80 ºC, no matter the
Temperature of Fanless is enabled or not.
Use the
Temperature Of Fanless
option to configure default temperature setting. When
the environment temperature is lower than default temperature setting, the fan will be
switched off. When the environment temperature is higher than default temperature
setting, the fan will be switched on. (The environment temperature depends on the
Environment Temperature 1
.) A list of available options is shown below:
Disabled
Disabled the Temperature Of Fanless function
4 C
When the environment temperature is lower than 4 C,
the fan will be switched off.
8 C
When the environment temperature is lower than 8 C,
the fan will be switched off.
12 C
When the environment temperature is lower than 12 C,
the fan will be switched off.
16 C
When the environment temperature is lower than 16 C,
the fan will be switched off.
20 C
When the environment temperature is lower than 20 C,
the fan will be switched off.
Summary of Contents for AFL2-17AB-H61 Series
Page 15: ......
Page 17: ...AFL2 17AB H61 Page 1 1 Introduction Chapter 1...
Page 29: ...AFL2 17AB H61 Page 13 2 Detailed Specifications Chapter 2...
Page 35: ...AFL2 17AB H61 Page 19 3 Unpacking Chapter 3...
Page 40: ...AFL2 17AB H61 Page 24 4 Ins tallation Chapter 4...
Page 70: ...AFL2 17AB H61 Page 54 Chapter 5 5 Sys tem Motherboard...
Page 106: ...AFL2 17AB H61 Page 90 Figure 5 36 LCD panel Selection Jumper Location...
Page 107: ...AFL2 17AB H61 Page 91 6 Sys tem Maintenance Chapter 6...
Page 116: ...AFL2 17AB H61 Page 100 7 BIOS Setup Chapter 7...
Page 153: ...AFL2 17AB H61 Panel PC Page 137 8 Cooling Management Cons ole iCMC Chapter 7...
Page 162: ...AFL2 17AB H61 Panel PC Page 146 Appendix A A Regulatory Compliance...
Page 167: ...AFL2 17AB H61 Panel PC Page 151 B Safety Precautions Appendix B...
Page 173: ...AFL2 17AB H61 Panel PC Page 157 C BIOS Menu Options Appendix C...
Page 176: ...AFL2 17AB H61 Panel PC Page 160 D Hazardous Materials Dis clos ure Appendix D...