AFL3-W15C/W19C/W22C-ULT3 Panel PC
Page 132
NOTE:
The Watchdog Timer is activated through software. The software
application that activates the Watchdog Timer must also deactivate it
when closed. If the Watchdog Timer is not deactivated, the system will
automatically restart after the Timer has finished its countdown.
EXAMPLE PROGRAM:
; INITIAL TIMER PERIOD COUNTER
;
W_LOOP:
;
MOV
AX, 6F02H
;setting the time-out value
MOV
BL, 30
;time-out value is 48 seconds
INT
15H
;
; ADD THE APPLICATION PROGRAM HERE
;
CMP
EXIT_AP, 1
;is the application over?
JNE
W_LOOP
;No, restart the application
MOV
AX, 6F02H
;disable Watchdog Timer
MOV
BL, 0
;
INT
15H
;
; EXIT ;
Summary of Contents for AFL3-W22C-ULT3
Page 17: ...AFL3 W15C W19C W22C ULT3 Panel PC Page 1 1 Introduction Chapter 1...
Page 30: ...AFL3 W15C W19C W22C ULT3 Panel PC Page 14 2 Unpacking Chapter 2...
Page 35: ...AFL3 W15C W19C W22C ULT3 Panel PC Page 19 3 Installation Chapter 3...
Page 72: ...AFL3 W15C W19C W22C ULT3 Panel PC Page 56 4 BIOS Setup Chapter 4...
Page 107: ...AFL3 W15C W19C W22C ULT3 Panel PC Page 91 5 System Maintenance Chapter 5...
Page 112: ...AFL3 W15C W19C W22C ULT3 Panel PC Page 96 6 Interface Connectors Chapter 6...
Page 131: ...AFL3 W15C W19C W22C ULT3 Panel PC Page 115 Appendix A A Regulatory Compliance...
Page 137: ...AFL3 W15C W19C W22C ULT3 Panel PC Page 121 B Safety Precautions Appendix B...
Page 143: ...AFL3 W15C W19C W22C ULT3 Panel PC Page 127 C BIOS Menu Options Appendix C...
Page 146: ...AFL3 W15C W19C W22C ULT3 Panel PC Page 130 Appendix D D Watchdog Timer...
Page 149: ...AFL3 W15C W19C W22C ULT3 Panel PC Page 133 Appendix E E Hazardous Materials Disclosure...