AUPS Series Power Module User Manual
Page 10
1.5.2 AUPS-B10/AUPS-B20 Battery
Specifications
Remarks
AUPS Model
AUPS-B10/AUPS-B20
--
Battery Pack
8 cells
4S2P
Battery Type
Li-ion
--
Nominal Capacity
5200 mAh
0.5C charge/0.2C discharge at 25
±
3°C,
cut off voltage at 2.75 V/cell
Minimum Capacity
5000 mAh
0.5C charge/0.2C discharge at 25
±
3°C,
cut off voltage at 2.75 V/cell
Nominal Voltage
14.52 V
0.5C charge/0.2C discharge at 25
±
3°C,
cut off voltage at 2.75 V/cell
End of Discharge Voltage
11 V
FD set 11 V
Charge Voltage
0~10°C
11~45°C
46~60°C
Charging Voltage
16800 mV
16800 mV
16400 mV
Rated Charge Current
0~10°C
11~45°C
46~60°C
Per cell
≦
2.75V
510 mA
510 mA
510 mA
2.75V
≦
Per cell
≦
4.1V
1530 mA
2550 mA
2550 mA
4.1V
≦
Per cell
≦
4.2V
1530 mA
2550 mA
0 mA
Pre-charge Current
510 mA (cell < 2.75 V)
Gas-gauge reports charge current as
510 mA
Max. Continuous Discharge
Power
100 W
Environment temp.: 0~40°C
Discharge from 100% to 0%
Max. Continuous Discharge
Current
7.5 A
Environment temp.: 0~40°C
Discharge from 100% to 0%
Max. Discharge Current
9.36 A
Duration time < 5 sec.
Pack Operating Temp.
0~40°C
Max. Humidity: 85% RH
Summary of Contents for AUPS Series
Page 10: ......
Page 11: ...AUPS Series Power Module User Manual Page 1 Chapter 1 1 Introduction ...
Page 24: ...AUPS Series Power Module User Manual Page 14 Chapter 2 2 Unpacking ...
Page 28: ...AUPS Series Power Module User Manual Page 18 Chapter 3 3 Installation ...
Page 34: ...AUPS Series Power Module User Manual Page 24 Chapter 4 4 Software Application ...
Page 53: ...AUPS Series Power Module User Manual Page 43 Appendix A A Safety Precautions ...
Page 59: ...AUPS Series Power Module User Manual Page 49 Appendix B B Hazardous Materials Disclosure ...