AUPS Series Power Module User Manual
Page 9
Max. Discharge Current
9.36 A
Duration time < 5 sec.
Pack Operating Temp.
0~40°C
Max. Humidity: 85% RH
Storage Temperature
1 year: -20°C ~ +25°C
3 months: -20°C ~ +45°C
1 month: -20°C ~ +65°C
During storage, pack must be charged
to 40%~50% every 3 months.
Protection
Over Voltage Protection
Set:
≧
4.24
±
0.02V / cell (0
°
C ~ 45
°
C), delay time: 2~4 sec.
Reset: <4.10
±
0.02V / cell
Under Voltage Protection
Set:
≧
2.55
±
0.02V / cell, delay time: 2~4 sec.
Reset:
≧
2.75
±
0.02V / cell
Cell Shutdown Voltage
Protection
Cell
≦
2.35V, delay time: 30 sec.
Over Discharge Current
Protection (SW)
Set:
≧
10.04A, delay time 5~7 sec.
Reset: Current > -20mA, then 30 sec.
Over Discharge Current
Protection (AFE)
Set: 11.5~14.5A, typical 12.95A, delay time 31±4 mSec
Reset: after 30 sec, and then current < 5mA
Short-circuit Protection
Set:
≧
30
±
20%A, delay time: 700uSec~1200uSec, typical 916uSec
Reset: after 30sec, and then current < 5mA
Over Charge Current
Protection
Set:
≧
5.2A, delay time 2~4 sec.
Reset: Current < 20mA, then 30 sec.
Charge Over Temperature
Protection
Set:
≧
60
±
3
º
C, delay time: 2~4 sec
Reset:
<
45
±
3
º
C
Discharge Over
Temperature Protection
Set:
≧
70
±
3
º
C, delay time: 2~4 sec
Reset:
<
60
±
3
º
C
Table 1-3: AUPS-A10/AUPS-A20 Battery Specifications
Summary of Contents for AUPS Series
Page 10: ......
Page 11: ...AUPS Series Power Module User Manual Page 1 Chapter 1 1 Introduction ...
Page 24: ...AUPS Series Power Module User Manual Page 14 Chapter 2 2 Unpacking ...
Page 28: ...AUPS Series Power Module User Manual Page 18 Chapter 3 3 Installation ...
Page 34: ...AUPS Series Power Module User Manual Page 24 Chapter 4 4 Software Application ...
Page 53: ...AUPS Series Power Module User Manual Page 43 Appendix A A Safety Precautions ...
Page 59: ...AUPS Series Power Module User Manual Page 49 Appendix B B Hazardous Materials Disclosure ...