E C N-360A-ULT3 E mbedded S ys tem
P age 115
NOTE :
When exiting a program it is necessary to disable the Watchdog Timer,
otherwise the system resets.
E XAMP L E P R OG R AM:
; INITIAL TIMER PERIOD COUNTER
;
W_LOOP:
;
MOV
AX, 6F02H
;setting the time-out value
MOV
BL, 30
;time-out value is 48 seconds
INT
15H
;
; ADD THE APPLICATION PROGRAM HERE
;
CMP
EXIT_AP, 1
;is the application over?
JNE
W_LOOP
;No, restart the application
MOV
AX, 6F02H
;disable Watchdog Timer
MOV
BL, 0
;
INT
15H
;
; EXIT ;
Summary of Contents for ECN-360A-ULT3
Page 14: ...E CN 360A ULT3 E mbedded S ys tem Page 1 Chapter 1 1 Introduction ...
Page 21: ...E CN 360A ULT3 E mbedded S ys tem Page 8 Chapter 2 2 Unpacking ...
Page 25: ...E CN 360A ULT3 E mbedded S ys tem Page 12 Chapter 3 3 Ins tallation ...
Page 32: ...E CN 360A ULT3 E mbedded S ys tem Page 19 Chapter 4 4 S ys tem Motherboard ...
Page 75: ...E CN 360A ULT3 E mbedded S ys tem Page 62 Chapter 5 5 B IOS ...
Page 115: ...E CN 360A ULT3 E mbedded S ys tem Page 102 Appendix A A R egulatory Compliance ...
Page 121: ...E CN 360A ULT3 E mbedded S ys tem Page 108 Appendix B B S afety Precautions ...
Page 126: ...E CN 360A ULT3 E mbedded S ys tem Page 113 Appendix C C Watchdog Timer ...
Page 129: ...E CN 360A ULT3 E mbedded S ys tem Page 116 Appendix D D Hazardous Materials Dis clos ure ...