FLEX-BX100-ULT5
Page 19
Step 4:
Line up the notch on the PoE module with the notch on the connector. Slide the
PoE module into the socket at an angle of about 20º.
Step 5:
Push the other end of the PoE module down and secure the module with the
retention screw previously removed.
Step 6:
Re-install the PoE card cover.
Step 0:
3.6 M.2 SSD Installation (Optional)
The M.2 M-key slot allows installation of M.2 2280 cards. To install an M.2 card, please
follow the steps below.
Step 1:
Remove the eight retention screws from the top panel. Slide the two side covers
upwards to remove them. And then, lift the center cover off the system.
NOTE:
A
thermal pad is attached under the center of the center cover. Thus, more
strength is required when lifting the center cover.
Figure 3-7: Rear Cover Retention Screws
Step 2:
Locate the M.2 slot as shown in Figure 3-8.
Summary of Contents for FLEX-BX100-ULT5
Page 2: ...FLEX BX100 ULT5 Page ii Revision Date Version Changes January 14 2021 1 00 Initial release...
Page 12: ...FLEX BX100 ULT5 Page xii Figure 6 1 Main Board Layout Diagram 73...
Page 15: ...FLEX BX100 ULT5 Page 1 Chapter 1 1 Introduction...
Page 23: ...FLEX BX100 ULT5 Page 9 Chapter 2 2 Unpacking...
Page 27: ...FLEX BX100 ULT5 Page 13 Chapter 3 3 Installation...
Page 47: ...FLEX BX100 ULT5 Page 33 Chapter 4 4 BIOS...
Page 82: ...FLEX BX100 ULT5 Page 68 Chapter 5 5 Troubleshooting and Maintenance...
Page 86: ...FLEX BX100 ULT5 Page 72 6 Interface Connectors Chapter 6...
Page 100: ...FLEX BX100 ULT5 Page 86 Appendix A A Regulatory Compliance...
Page 105: ...FLEX BX100 ULT5 Page 91 B Safety Precautions Appendix B...
Page 111: ...FLEX BX100 ULT5 Page 97 Appendix C C BIOS Menu Options...
Page 114: ...FLEX BX100 ULT5 Page 100 Appendix D D Watchdog Timer...
Page 117: ...FLEX BX100 ULT5 Page 103 Appendix E E Error Beep Code...
Page 119: ...FLEX BX100 ULT5 Page 105 Appendix F F Hazardous Materials Disclosure...