prox.pad Plus IR Access System Installer Guide
Action Desired
Press
Details
Change Platform Parameters
32 # parameter # value # **
See Chart Below
Parameter
Value
0 – Error Lockout Threshold
1 – 50 Attempts (
Default = 3
)
1 – Error Lockout Duration
1 – 255 Sec. (
Default = 10 Sec.
)
3 – Extended User Unlock Time
1 – 255 Sec. (
Default = 10 Sec.
)
4 – Facility Code (For commands 51 & 57)
0 – 255 (
Default = 11
)
8 – Anti-Passback Delay
2 – 240 (¼ sec increments;
Default = 4, 1
sec)
Reset System Defaults Only
40 # 00000 # 00000 # **
Does not delete users
Set System Time
41 # hhmm # 0 # **
hhmm=hour/minute (24 Hour
Format)
Set System Date
42 # mmddyy # dow # **
mmddyy=month, date, year;
dow=day of week, 1=Sunday
Set Propped Door Time
44 # time # 0 # **
Time = 10-990 seconds;
(default=30 secs)
Set Forced Door Time
45 # time # 0 # **
Time =forced door time, to nearest
10’s seconds, entered as 30-990;
(
default=10 secs)
Delete Entire Memory and Reset
System Defaults
46 # 00000 # 00000 # **
Deletes all memory including users
Program User – Code Only
50 # user type # user location
#
code *repeat code *
User Types:
0 – Toggle
1 – Standard
3 – Lockout
4 – Extended
5 – Single Use
6 – Relock
7 – Emergency
8 – Communications Unlock
Program User – Code AND Card
By Presenting Card
50 # user type # user location #
code * repeat code ** <present
card>
User Types:
0 – Toggle
1 – Standard
3 – Lockout
4 – Extended
5 – Single Use
6 – Relock
7 – Emergency
8 – Communications Unlock
Document # 6105681, Rev 1.1, D2a Page 29 of 32