45
2
INSTALLATION PROCEDURE
302.061
ERROR
CAUSE
SOLUTION
The short feed flag was not knocked
down.
No bar.
Load new bars into the bar feeder
magazine.
ERROR
CAUSE
SOLUTION
The guide channel lifting levers do
not lower.
During the BAR CHANGE the guide
channel did not lower or the bar
drop control did not switch off.
Check the cylinder motion.
Check the lever lifting and channel
lifting sensors.
ERROR
CAUSE
SOLUTION
The machining cycle lasted longer
than the time set in
parameter 23.
The machining cycle required more
time than set in
parameter 23.
Check the settings of
parameter 23
based on the actual work cycle.
The machining cycle was stopped
or slowed down.
Check the effective length of the
work cycle and ensure that it is not
stopped or slowed down.
20
E r r o r : f l a g
n o t
k n o c k e d
21
E r r o r : n o
l e v e r
l o w e r i n g
22
E r r o r : w o r k p i e c e
t i m e
o u t