65
3
SETUP INFORMATION
302.061
3.1.3 Axis function parameter description
INFORMATION: Once the parameter values are set, the power supply must be disabled and then enabled again,
if the set values are to be self-learned.
It is recommended to avoid changing these parameters; if a change is necessary, call the IEMCA service depart-
ment.
Subparameters
70
n o . 7 0
A x i s
p a r a m e t r i n g
I n v E n
1
Mm I m p
2 8 5 7 , 5 ( mm / i m p . )
T i p A b
6
I n v V o
0
T y A z z
1
T o d A b
0
V e l M x
1 6 6 6 ( 2 5 0 0) ( mm /s e c )
P D f h
1 ( mm )
A l g C o
0
D e c E m
6 0 0 0 ( mm / s e c * s e c )
E r r E c
3 0 0 0 ( mm )
P r c F d
0 ( % )
K P P
1 4 0
K P M
1 5 0
K D
0
K I
1
I n L i m
1
C l e E i
1
T P
0 , 0 6 ( mm )
I P
0 , 0 0 ( mm )