Parameter
Description
PUSH AND GO
No
: a passage authorization unlocks the obstacle and its rotation is
driven by the motor.
Yes
: the passage authorization unlocks the obstacle. Its rotation must
be started manually, the motor assisting for the complete opening.
The obstacle locks again automatically if it has not been opened after 6
seconds (not adjustable).
The A
UTH
M
EMORISATION
parameter is not active if P
USH AND
G
O
is set
to Yes.
AUTONM./MASTER/
SLAVE
Autonomous
normal operation
Master/ Slave
only with IP option
AUTH. MEMORISATION
(TBV only)
Number of opening requests saved while the preceding movement is
still in progress. The stack of opening requests in one direction is
always cleared before accepting opening requests in the opposite
direction.
OPENING ANGLE A
WAY
(PPV only)
Fine adjustment of the maximum opening angle in the clockwise
direction (A direction), measured during the automatic configuration
(A
UTOMATIC
S
ETUP
section).
This adjustment may be necessary according to obstacle’s height.
Note
: adjust the limit stops after modifying this parameter (ch.5.7. ).
OPENING ANGLE B
WAY
(PPV only)
Fine adjustment of the maximum opening angle in the counter-
clockwise direction (B direction), measured during the automatic
configuration (A
UTOMATIC
S
ETUP
section).
This adjustment may be necessary according to obstacle’s height.
Note
: adjust the limit stops after modifying this parameter (ch.5.7. ).
TIME DELAY AFTER
CMD
Time delay between an opening command (badge, pushbutton, etc.)
and the actual unlocking (0 to 100 seconds).
STOP TIME DELAY
(PPV only)
Stop time in the open position before closing (0 to 100 s).
BRAKING ANGLE
Angle from which the obstacle speed decreases (cf. ch.4. ).
Note
: do not change this value, calculated during the automatic
configuration (A
UTOMATIC
S
ETUP
section) according to the obstacle
dimensions and inertia.
DIR.EMERGE.OPENING
(PPV only)
Direction of obstacle opening on an Emergency (FIRE) command
(ch.4.3. ): clockwise (A) or counter-clockwise (B)
ROTATION SPEED
Adjustment of the obstacle’s opening and closing speed (5 to 40, 22 by
default).
Note
: proceed to an A
UTOMATIC
S
ETUP
after each modification of this
parameter!
NUMBER OF WARNING
Number of successive attempts to complete the opening or closing
movement, before the equipment is put out of service and the error
message is displayed and a signal is sent to the CPU output.
LANGUAGE
Menu language selection: French / English.
FUNCTIONAL TEST
Continuous clockwise and anti-clockwise opening cycles.
Exit the mode by pressing on the STOP button.