5.2. Turning the equipment ON/OFF
5.3. Preventive maintenance
Every 100,000 operations, or every 6 months, whichever comes first, check the following points:
The security of all components (attachment to the floor, obstacle, motor, conical coupling (4, p 6),
etc.).
The state of the ground cable on the rotor (Fig. A).
The control signals.
The opening and closing speeds.
The obstacle opening and closing angles and positions.
The activation of the locking mechanism in the closed position.
The unlocking in case of a power outage.
The obstacle opening in case of an emergency command (opening of the Fire contact on the power
board, see electric diagrams).
Any output signals to optional peripheral equipment.
Clean the stainless steel surfaces and glasses by means of an appropriate product.
Every 800,000 operations, replace the locking mechanism (ch.5.8. ).
Fig. A: connection of the rotor to the ground