The information contained in this document is the property of Automatic Systems and is confidential. The recipient shall refrain from using it for any purpose other than the use of the products or the
execution of the project to which it refers, and from communicating it to third parties without Automatic Systems’ prior written agreement. Document subject to change without notice.
BL3x-MT-EN-08
page
53/59
8.1.
Control blocks assignment
Connector block number
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
A
GND
GND
GND
GND
24V
24V
24V
GND
GND
GND
REL3 -
Output relay 3
REL3 +
Output relay 3
GND
GND
GND
GND
B
AO1
FI setting
DO11 PWM
Output 11
DO8
Descending motor
24V
DI13
Closing LS
DI11
Lock Close CMD
DI9
Close command
24V
24 V
24V
REL2 -
Output relay 2
REL2 +
Output relay 2
24V
24V
24V
24V
Connectors
C
AI1
Analog. Sensor
DO10sPWM
Output 10
DO7
Rising motor
DI14
cr
ank limit switch
DI12
Opening LS
DI10
Lock Open CMD
DI8
Open command
DI7
Stop command
DI6
Reader A command
DI5
Swing off sens./Lock
REL1 -
Output relay 1
REL1 +
Output relay 1
DI4
Cell 4
DI3
Cell 3
DI2
Cell 2
DI1
Cell 1
A In/Out
B connector
blocks.
C
X13 Inductive
loops
X14 connectors.
X9
Connectors for
X11 inductive loops presence
detectors.
Y
Inductive loops presence
detector.
A
B
C
1 2 3 4 5 6 ............................ 16
X14
X11
DP1
DP2
DP3
DP4
Y
DP1
DP2
DP3
DP4
X13
X9