PNG3XX INSTALLATION MANUAL
NAM-PNG3xx-TM-EN-C.doc
The info rmation contained in this d ocu ment is the p roperty of Auto matic
Syste ms and is co nfidentia l. The re cipient shall refrain fro m using it fo r a ny
purpose other than the use of the pro ducts or the execu tion of the pro ject to
which it refers and fro m co mmunicating it to third partie s without written p rio r
agree ment of Auto matic Syste ms. Do cu ment sub ject to change without notice.
30
2.8 Wiring Principle for One Lane:
Hi
Vo
ltag
e In
terc
onn
ect
Low Voltage Interconnect
Motor
J.B.
PUBLIC (UNSECURED) SIDE
DIRECTION A - ENTRY
LoVolt
Term.
120VAC
Motor
J.B.
From Access Sys.
X6
Power
In JB
SECURE SIDE
DIRECTION B - EXIT
X13
Interface
Board
Figure 23: Wiring Principle for Single Lane
•
Only one branch circuit of 120VAC is required
•
Both low voltage and high voltage conduit are required
•
Right Unit is the Master Unit
•
Access Control Wiring enters the Master unit
•
Refer to Figure 33 for complete interconnect instruction