www.ies-synergy.com
User Manual
DIM016199-EN
31
Message
Description
“PSU OVERVOLTAGE”
Overvoltage detected by power supervisor (internal).
“PSU OVERHEATING”
Overheating detected by power supervisor (internal).
“PSU COHERENCY”
Coherency error detected by power supervisor (internal).
“PSU INSULATION”
Earth fault detected by power supervisor (internal).
“PSU LIMIT Vmax”
Output voltage limit exceeded (+5V) detected by power supervisor
(internal).
“PSU SHORT CIRCUIT”
Output short-circuit detected by power supervisor (internal).
“PSU Bad Vred”
Input voltage out-of-range detected by power supervisor (internal).
“OverCurrent”
Output current exceeds the maximum value
“ERR EV Charge Status Not
Ready”
The vehicle requests a charge but its status is not ready.
“ERR Bad Pilot State during
charge”
The pilot changes from status C during charging
“EV bad pilot state at start”
Pilot status is not A or B at start
“Error EV Not Ready”
The EV ready flag is not ready
“Error Timeout : EV Session Setup
Request not received”
The charger has not received the session setup request (timeout is
20 s)
“Error Timeout : EV Ready to
Charge State not received”
The charger has not received the ready to charge flag (Timeout is
40s)
“Error No message or Client Dis-
connected”
The charger has detected that the EV is present, but the EV has not
sent a request.