Hardware Operations
1230B0049701
2-6
2.3.2
To install the motherboard
Reverse the steps above to install the motherboard.
2.4
Power Distribution Board
The two 700W hot-swappable power supplies are designed with a power distribution board.
All the power cables come out from the power distribution board.
The location of power distribution board on the server chassis is shown below:
Figure 2-8 Power Distribution Board Location
Reminder
Before you remove or install the power distribution board, please follow the steps below:
Step 1: Make sure the server is not turned on or connected to the AC power. To power off
the server, see “2.1.1 Power Off”.
Step 2: Remove the chassis cover. To remove the cover, see “2.2 Chassis Cover”.
Step 3: Remove the power supplies. To remove the power supplies, see “2.5 Power
Supplies”.
Step 4: Disconnect all necessary cable connections.
Do not overly tighten the thumbscrews. Doing so may damage the motherboard.