Hardware Operations
1230B0049701
2-9
2.5.1
To remove the power supply
Press the retaining clip on the right side of the power supply along the direction of the
arrow.
At the same time, pull out the power supply by using its handle. (The power supply takes
considerable force to remove.)
Figure 2-12 Removing the Power Supply
2.5.2
To install the power supply
Insert the replacement power supply firmly into the bay until the retaining clip snaps back.
Connect the AC power to the replacement power supply.
Figure 2-13 Installing the Power Supply
2.6
System Fan Assemblies
This server contains two groups of hot-swappable system fans seated in the system fan
cages, which are located inside the chassis. These two groups of system fans respectively
locate in system fan cage 1 and system fan cage 2. The system fan cage 1 supports three
sets of system fans and the system fan cage 2 supports two system fans. These system fans
maintain the ideal temperature for the motherboard, backplane and disk drives. If one system
fan fails, the speed of other system fans will increase. With the bad one replaced, the other
system fans may revert to the normal speed.