iesy GmbH
www.iesy.com | sales@iesy.com | Tel.: +49 (2354) 70655 0
Local court Iserlohn | HRA 9826 |
USt-IdNr
: DE339671635 | Managing Director: Dipl.-Ing. Martin Steger
Seite 11 von 27
User Manual V-180131-BHA00
If a power unit is defective, you can replace the power unit.
1.
switch off the SDoT Server V3B and remove it from the power supply
2.
pull the plug out of the defective power supply unit
3.
press the black locking lever in the direction of the bow handle
4.
while holding the lever, pull the power supply out of the housing by the metal bracket
5.
check that the replacement power supply corresponds to the required type
Manufacturer: 3Y Power Technology
Model:
YM-2301E
Power:
300 W
Input:
0-240 V AC, 3.0-5.0 A, 50-60 Hz
Output:
+12 V DC, 24 A; Standby: +5 V, 3 A
6.
hold the new power supply with the label facing up and the metal bracket facing back
7.
slide the new power supply into the free slot until the power supply is fully engaged
8.
plug the connector back into the power supply