Final stage of installation
Place wind insulating covering around
the joints of the indoor unit and fix it
with insulating tape.
Fix the exceeding part of the signal cable
to the piping or to the outdoor unit.
Fix the piping to the wall (after having
coated it with insulating tape) using
clamps or insert them into plastic slots.
Seal the hole in the wall through which
the piping is passed so that no air
Or water can fill.
Note
The electronic controller starts
the compressor three minutes after voltage
has reached the system.
Do ON/OFF and fan operate normally?
Do the various modes operate normally?
Does the Timer function properly?
Does each LED function normally?
Do the flaps for airflow direction
operate normally?
Is the condensed water drained
regularly?
Indoor unit test
Is there any abnormal noise or vibration
during operation?
Could the noise, airflow or condensed
water drainage disturb the neighbours?
Is there any coolant leakage?
Outdoor unit test
35