34
6
MAINTENANCE
1
26
20
030
0.
fm
CLEANING THE COLD ACCUMULATORS
(HYBRID FUNCTION)
IMPORTANT!
Carry out the "CLEANING" function before accessing the bottom of the
tank. Complete melting of the ice allows for easier and safer working.
Clean the cold accumulators at least once per year.
Proceed as indicated.
IMPORTANT!
Before performing any operation, switch off the equipment using the con-
trol panel and move the electrical master switch to OFF.
- Remove the pans
(A)
.
- Remove the cross mem-
bers
(B)
.
- Remove the pans support
cross bars
(C)
.
- Unscrew the fixing bolts
and remove the panels
(D)
.
- Extract the cold accumula-
tors
(E)
and clean them.
The first container to the right
(operator side) is equipped
with a thermostatic probe. It
must be removed and, after
operations, must be returned
to its housing.
- Clean the containers with warm water.
- Repeat the operations in reverse.
IMPORTANT!
Position the cold accumulators with the closure taps aimed upwards.
E
D
A C B