Page
6
2.1 AC Connection and Set-Up
If your amplifier is equipped with a MS Connector for a power connection, the following instructions
will assist a qualified technician to wire the supplied mating MS Connector.
Determine whether your amplifier is Single Phase or Three Phase by locating the Serial Number
Label and noting the Phase (PH) identification. The Serial Number Label is located on the rear panel
of the amplifier.
Located near the Power Connector is a wiring illustration as pictured below. If the unit requires
Three Phase wiring, all pins illustrated are utilized, if the unit requires Single Phase, only the Pins
identified with the “Used on Single Phase” lines are utilized which are Pins A, D and E.
Note 1:
Pin letters are case sensitive, should the provided connector
contain lower case letters, use only the upper case letters as shown.
Note 2:
Wiring should be performed by qualified personnel and in
accordance to applicable electrical standards using the appropriate wire
colors, size and current considerations.