14

15

1)           Begin in a seated position. Press 
the safety latch on the buckle rearward in 
order to lift the buckles and unbuckle 
the cables.  

1)  Follow the manufacturer’s directions 
for cleaning the silicone locking liner.  
Make sure to clean the silicone part which 
contacts the skin every day with soap and 
water to prevent infection.

7)  Once buckled, stand up to test out the 
tightness. If too tight or too loose, return 
to a seated position, and move the buckle 
either one notch forward or one back for 
adjustment.  

 

   If the socket causes pain when 

buckled contact your healthcare provider. 

2)  The padded inner liner may be taken 
out and washed on a gentle cycle then 
air dried.  It is very important you do not 
put the liner in the drier as high heats may 
cause damage.

3)  When replacing the liner back into the 
prosthesis, make sure it is properly aligned 
with the prosthesis.

If the liner starts to show any signs of wear, 
a replacement should be ordered.

4)  Check your cables periodically to make 
sure they are not fraying.  

If any issues arise, make sure to contact your prosthetist.

Most issues may be resolved by adding padding in an area or making 
an alignment adjustment.  

We hope you enjoy your new iFIT Prosthesis!

2)  Next, press the clutch release button 
located on the front of the device to disen-
gage the pin.  The limb should easily slide 
out of the prosthesis.

STEP C: TAKING OFF THE DEVICE

STEP D: CLEANING AND MAINTENANCE

Summary of Contents for TT200

Page 1: ...Patient User s Guide MODEL TT200 www iFitProsthetics com The Right Fit Right Now...

Page 2: ...Instructions 11 Step A Initial Device Check 11 Step B Putting on the Device 12 Step C Taking off the Device 14 Step D Cleaning and Maintenance 14 Secton IV Wear Schedule 16 Get the right fit today A p...

Page 3: ...e 16 so you can check your residual limb and gradually adjust to the device Even though the iFIT Prosthesis is designed to be easily fit and aligned we recommend that only an iFIT certified prosthetis...

Page 4: ...are provider The prosthetic socket must be securely buckled at all times when you are standing or walking The buckles must be completely closed so that the locking mechanism prevents them from opening...

Page 5: ...is Upon timely return of such prosthesis or sockets buckles or locks as applicable and provided iFIT confirms that the prosthesis or sockets buckles or locks as applicable included a manufacturing def...

Page 6: ...s 4 The outer flap of the prosthesis should have the cable guides with the cables passing through it and attaching to the hooks The inner flap is smooth and slides under the outer flap Section III Ins...

Page 7: ...hould be marked off by the healthcare provider You may need to start looser and then gradually tighten the cables by buckling and re buckling until the optimal hook is reached The prosthesis can be lo...

Page 8: ...ay be taken out and washed on a gentle cycle then air dried It is very important you do not put the liner in the drier as high heats may cause damage 3 When replacing the liner back into the prosthesi...

Page 9: ...DAY 1 Wear 2 hours Check limb If no issues Wear 2 Keep off for additional hours 5 minutes DAY 2 Wear 3 hours Check limb If no issues Wear 3 Keep off for additional hours 5 minutes DAY 3 Wear 4 hours...

Page 10: ...ssion is to produce high quality affordable prosthetic devices that enhance the lives of persons with amputations iFIT Prosthetics is a proud veteran owned American business making products in Milwauk...