iFLOW HVAC INC.
www.iflowhvac.com
2) Standard Features and Benefits:
• Highest performance at 98% efficiency (CAN/CAS P.9-11
Performance Ratings: TPF 0.98)
• Ultra-efficient heat-exchanger design with high-density aluminum
fins
• Offers installation flexibility allowing for up-flow, down-flow or
horizontal applications
• Cost effective and extremely quiet variable speed ECM fan motor /
constant CFM
• Slide-out blower rail assembly for easy maintenance & removal with
4 screws
• 6 fully modulating models: 3 ‘standard duct’ models (S, M, L) & 3
high-static pressure models (S, M, L)
• Easy installation: Lightweight, “one-man job” with Optional EZEE
Plumbing Kit
• Approved for potable water (‘open’) systems with buit-in anti-
stagnation and DHW priority included in the control board
• Air and water supply and return temperature sensors included
• Humidity sensor included for cooling fan speed modulation
• Freeze Protection/ Evaporator Temperature Sensor
• Outdoor temperture sensor included
• Intelligent iFLOW control board
• All models are compatible with mercury or digital thermostats
• Supports the use of two stage and inverter-driven variable speed
cooling equipment
• Accessories are controlled by AC24V power
• LED light indicates alarm, test mode and normal operation
• Auxiliary contacts (dry contact) for boiler or water heater activation
• Bottom or left or right side return air supply
• 0” clearance to combustibles
• Cabinet lined with 1/2” Polyethylene High-Density Insulation
• Cabinet manufactured with heavy gauge galvanized steel and
powder-coated to prevent corrosion
iNTELLIGENT PUMP CONTROL:
• Pump modulation control
• Low flow pump exercise function (Water Circulation / Seize
Protection)
• Low ambient freeze protection
iNTELLIGENT CONTROL:
• Boiler demand control
• Installer & user-friendly interface
• Informative display: error code, temperture, humidity, fan & pump
speed
• Easily configure all parameters smartphone App.
• 22 segment LED indicator / all input & output signals: built-in
programmable and diagnostic control display
• Outdoor reset function / outdoor temperature sensor
• Full modulation a single or two stage settings for heating & cooling
• Humidity control / humidity sensor
• ΔT auto-adjustment air and water (air and water flow control)
• Fan "ON" delay & Fan "OFF" heat purge control
5
• DHW priority & dual mode (heating and DHW)
• High & low limit safety control: air temperature sensor
• Home freeze protection: low ambient temperature sensor
• Evaporator freeze protection: compressor protection
• Virtual termostat mode with the smartphone app
• Smart zoning control (saving gas & hydro)
• Maximize heat pump performance / (AVOID) Peak Time AVOID
Electricity Function
• Hybrid heating system switching control and backup with heat pump
• Communication with NAVIEN Tankless Water Heater
OPTIONS:
• Multi-system central control for building HVAC systems
• Wi-Fi connection with a smartphone (Free app available on iOS and
Android)
• Remotely adjust and monitor operation through web integrated plug-
in control, or directly via a smartphone connection
• All-in-one package (EZEE plumbing kit and stand) for easy
Installation: iFLOW AHU with any TLWH/TWH
Freeze Protection:
iFLOW Air handlers include a freeze protection sensor that will
temporarily disable the outdoor condenser for 5 minutes if the
evaporator coil outlet temperature drops below 40°F/4°C. This will
allow the system to warm up and return back to normal operating
conditions.
To protect the hydronic heating coil from freezing, the pump will
operate for a minimum of 30 seconds. Dirty air filters, oversizing of A/
C equipment, improper A/C installation or poor duct design will also
play a role in the evaporator coil freezing.
Water Circulation / Pump Exercise:
In section 4.2.5.1 Prevention of Stagnation of the 'CAN/CSA-B214-12
Installation Code for Hydronic Heating Systems', it states: "a means
shall be provided to prevent the stagnation of potable water in a
hydronic system by recycling or flushing the contents not less than
once every 24 hours."
The iFLOW controller is defaultset to turn on the circulating pump to
cycle the total volume of potable water in the system, once every 24
hours. This will prevent stagnation and protect the pump from seizing.
There is a test button to verify that this operation is working. The
setting can be adjusted to circulate more frequently if desired.
Alarms:
In the event of a service problem (i.e. temperature sensor failure, low
ambient temperature, cooling lockout, etc.), the iFLOW air handler
will notify the user/owner with an audible alarm and red light. The
alarm on the control board can be silenced by turning the power off
for 5 seconds and then back on.
Summary of Contents for iFLH-14000W
Page 24: ...iFLOW HVAC INC www iflowhvac com SZ Field Installation Wiring Diagram 24 See Details Page 29...
Page 26: ...iFLOW HVAC INC www iflowhvac com DZ Field Installation Wiring Diagram 26 See Details Page 29...
Page 28: ...iFLOW HVAC INC www iflowhvac com QZ Field Installation Wiring Diagram 28...
Page 30: ...iFLOW HVAC INC www iflowhvac com 4 Ladder Diagram 30...
Page 43: ...iFLOW HVAC INC www iflowhvac com 43 Installation on the wall...