P
RESET
C
OUNTER
E89005
P
AGE
6
Permanent signal of output 2,
activated at count value
>
preset 2
in adding mode and at count value
<
zero in subtracting mode*
Permanent signal of output 2, will
become passive at count value
>
preset 2 in adding mode and at
count value
<
zero in subtracting
mode**
Timed signal of output 2, will beco-
me passive at count value = preset
2 in adding mode and at count
value = zero in subtracting mode**
Timed signal of output 2, activated
at count value = preset 2 in adding
mode and at count value = zero in
subtracting mode*
Duration of timed signal of output 2,
can be set from 00.01 s to 99.99 s.
* Activation of relay coil when rea-
ching the preset value
** Relay coil becomes dead when
reaching the preset value
Gate time
= within this period the
incoming pulses will be counted
and displayed.
Programmable range from 00.01 s
to 99.99 s
Setting with
←
and
↑
-keys
00.00 won’t be accepted
Polarity of the inputs:
pospol: positive polarity (PNP)
switching to +24 V
negpol: negative polarity (NPN)
switching to 0 V
Input modes:
E1:
INP A = count input
INP B = count direction input
E2:
INP A = count input adding
INP B = count input subtr.
E3:
Quadrature input
INP A = count input 0°
INP B = count input 90°
E4:
same as E3, but with pulse
doubling.
Each pulse edge of INP A will
be counted.
Scaling factor:
0.0001…9.9999
Setting with
←
and
↑
-keys
Factor 0.0000 won’t be accepted
Decimal point
(only optical function):
0
= no decimal point
0.0
= one decimal place
0.00 = two decimal places
0.000 = three decimal places
6.2.3 Programming routine Frequency Meter