P
RESET
C
OUNTER
E89005
P
AGE
9
Output 2:
Relay with potentialfree change-over
contact
switching voltage max. 250 VAC / 300 VDC
switching current max. 3 A
switching current for DC min. 30 mA
switching performance max. 50 W for
DC and max. 2000 VA for AC
Responding time of outputs:
Relay:
approx. 6 ms
Data retention:
min. 10 years or 10
6
memory cycles
Transmitter voltage:
24 VDC –40% / +15% 60mA
unstabilized
Fuse protection:
recommended fuse
for 230 VAC: 0,05 AT
for 115 VAC: 0,1 AT
Noise immunity:
EN 55011 class B and EN 50082-2
with shielded data inputs
Ambient temperature:
0…50°C
Storage temperature:
–25°C…+70°C
Weight:
approx. 240 g
Protection: IP 65 (front)
Colour of housing:
black
Cleaning:
The front of the unit is only to be cleaned
with a soft and wet (water!) cloth.
11. Delivery includes
– Counter 904
– Screw terminal plug 7 poles, reference grid 5.08 mm
– Screw terminal plug 7 poles, reference grid 3.81mm
– Bezel for screw mount, panel cut-out 50 x 50mm
– Bezel for clip mount, panel cut-out 50 x 50 mm
– Bezel for clip mount, panel cut-out 45 x 45 mm
– Panel mounting clip
Dimensions:
panel cut-out 45 x 45 mm
with front frame N0. 3
panel cut-out 50 x 50 mm
with front frame No. 2
panel cut-out 50 x 50 mm