9
UK
4.3 Installation and adjustment of the camera
Installation (example)
1� Determine a suitable installati-
on location (→ 4.4 Installation
6,5
2� Bore the holes for the lower part
of the universal mounting clamp�
Borehole spacing = 25 cm�
3� Fix the lower part of the mounting
clamp with the M6 screws,
washers and self-locking nuts
supplied with the unit�
Max� tightening torque 11 Nm
(± 1 Nm)�
4� Insert the camera in the lower part
of the clamp� Fix the upper part
with the supplied M3 socket head
screws�
5� Align the camera to the area to be monitored� Fix the mounting clamp with a
max� tightening torque of 0�8���1 Nm�
6� Provide for a borehole of d = 19 mm for the cable entry in the cabin / termi-
nal chamber� Insert the camera cable and seal the cable entry with the freely
positionable rubber grommet (1)�
The minimum bending radius of the camera cable of 50 mm must be
observed�