13
UK
Liquids
Medium temperature [°C] .................................................................................... -25 ... +80
Setting range [cm/s]..................................................................................................3 ... 300
Greatest sensitivity [cm/s] ..........................................................................................3...100
Temperature gradient [K/min] .........................................................................................300
Gases
Medium temperature [°C] .................................................................................... -25 ... +80
Setting range [cm/s]............................................................................................200 ... 3000
Greatest sensitivity [cm/s].....................................................................................200 ... 800
Switch point accuracy [cm/s] ................................................................................± 2...± 10
2)
Hysteresis [cm/s] ..........................................................................................................2...5
2)
Repeatability [cm/s] ......................................................................................................1...5
2)
Temperature drift [cm/s x 1/K].........................................................................................0.1
3)
Response time [s] .......................................................................................................1 ... 10
Pressure resistance [bar].................................................................................................300
Operating temperature [°C] .................................................................................... -25 ... 80
Protection rating ........................................................................................................... IP 67
Protection class ..................................................................................................................III
Shock resistance [g] .............................................................. 50 (DIN / IEC 68-2-27, 11 ms)
Vibration resistance [g] ...................................................20 (DIN / IEC 68-2-6, 55-2000 Hz)
Housing materials ......................stainless steel 316L / 1.4404; stainless steel 304 / 1.4301;
PC (Makrolon); PBT-GF 20; EPDM/X (Santoprene)
Materials (wetted parts) .......................................................................... Hastelloy (2.4610);
O-ring: FPM 8x1.5 gr 80° Shore A
EMC
EN 61000-4-2 ESD: ................................................................................ 4 kV CD / 8 kV AD
EN 61000-4-3 HF radiated: ...................................................................................... 10 V/m
EN 61000-4-4 Burst: ..................................................................................................... 2 kV
EN 61000-4-6 HF conducted: ....................................................................................... 10 V
1)
to EN50178, SELV, PELV;
2)
for water; 5...100 cm/s; 25°C (factory setting)
3)
for water; 5...100 cm/s; 10...70°C
The sensor conforms to the standard EN 61000-6-2
More information at www.ifm.com