Operating instructions 

Pressure sensor

PN73xx

704783 / 00

 

 05 / 2010

UK

Summary of Contents for efector 500 PN73 Series

Page 1: ...Operating instructions Pressure sensor PN73xx 704783 00 05 2010 UK...

Page 2: ...figuring the display optional 12 9 3 Setting the output signals 12 9 3 1 Setting of the output function 12 9 3 2 Setting of the switching limits 12 9 4 User settings optional 13 9 4 1 Setting of a tim...

Page 3: ...cument prior to set up of the unit Ensure that the product is suitable for your application without any restrictions If the operating instructions or the technical data are not adhered to personal inj...

Page 4: ...exceeded only for a short time the unit may be destroyed NOTE Risk of injury Use in gases at pressures 363 PSI 25 bar only after contacting the manufacturer ifm High pressure units 400 bar are supplie...

Page 5: ...nction normally closed OUx Fnc fig 2 The width of the window can be set by means of the difference between SPx and rPx SPx upper value rPx lower value 1 2 P system pressure HY hysteresis FE window 4 3...

Page 6: ...n The national and international regulations for the installation of electrical equipment must be adhered to Voltage supply to EN50178 SELV PELV Disconnect power Connect the unit as follows 2 x p swit...

Page 7: ...switching state of the corresponding output 9 Alphanumeric display 4 digits Indication of the current system pressure Indication of the parameters and parameter values 10 Set pushbutton Setting of the...

Page 8: ...8 8 Menu 8 1 Menu structure...

Page 9: ...tion for OUT2 Switching signal for the pressure limit values hysteresis function H or window function F either normally open no or normally closed nc Diagnostic signal OU2 dESI EF Extended functions o...

Page 10: ...er flashes for 5 s After 5 s setting value is changed incrementally by pressing the button once or continuously by keeping the button pressed Numerical values are incremented continuously To reduce th...

Page 11: ...t parameter of the sub menu is displayed here Uni Locking unlocking The unit can be locked electronically to prevent unintentional settings Make sure that the unit is in the normal operating mode Pres...

Page 12: ...ect OU1 and set the function Hno hysteresis function normally open Hnc hysteresis function normally closed Fno window function normally open Fnc window function normally closed Select OU2 and set the...

Page 13: ...e damping for the switching outputs Select dAP and set a value dAP value response time between pressure change and change of the switching status in milliseconds The following fix values can be set th...

Page 14: ...arameter is displayed Press Set briefly The unit displays the corresponding parameter value for about 15 s After another 15 s the unit returns to the Run mode 10 2 Fault indication OL Overload pressur...

Page 15: ...15 UK 11 Scale drawing Dimensions are in millimeters 1 display 2 LED s 3 programming button...

Page 16: ...0 K Greatest TEMPCO of the zero point of the span 0 2 0 2 Materials wetted parts stainless steel 303S22 ceramics FPM Viton Housing material stainless steel 304S15 stainless steel 316L 1 4404 PBTP Poca...

Page 17: ...398 2 MPa 0 4 40 0 0 2 39 8 0 2 PN7302 PSI 20 1450 10 1440 10 bar 1 0 100 0 0 5 99 5 0 5 MPa 0 10 10 00 0 05 9 95 0 05 PN7303 PSI 4 362 2 360 2 bar 0 2 25 0 0 1 24 9 0 1 MPa 0 02 2 50 0 01 2 49 0 01 P...

Page 18: ...R rP1 23 VMR OU1 Hno OU2 Hno SP2 75 VMR rP2 73 VMR dS1 0 0 dr1 0 0 dS2 0 0 dr2 0 0 P n PnP dAP 60 diS d2 Uni PSI the indicated percentage of the final value of the measuring range VMR of the correspon...