background image

Operating instructions 

Compressed air meter

SD2001

11406630 / 

00    10 / 2013

UK

Summary of Contents for efector300 SD2001

Page 1: ...Operating instructions Compressed air meter SD2001 11406630 00 10 2013 UK...

Page 2: ...llation 8 5 1 Installation location 8 5 2 Installation conditions 8 5 3 Mounting position 9 5 4 Installation in pipes 10 6 Electrical connection 10 7 Operating and display elements 11 8 Menu 12 8 1 Me...

Page 3: ...he measured values 17 9 4 4 Setting the error behaviour of OUT1 OUT2 17 9 5 Service Funktionen 18 9 5 1 Reading the min max values for volumetric flow 18 9 5 2 Reset all parameters to the factory sett...

Page 4: ...andstill and no pressure is applied before mounting components into or removing them from compressed air equipment Improper or non intended use may lead to malfunctions of the unit or to unwanted effe...

Page 5: ...e 4 Function 4 1 Processing of the measured signals The unit displays the current process values It generates 2 output signals according to the parameter setting OUT1 3 selection options parameter set...

Page 6: ...in ImPS is reached 9 3 1 4 3 2 Consumed quantity monitoring with preset meter 2 types of monitoring are possible Time dependent quantity monitoring Settings ImPS quantity x ImPR no rTo time t If the...

Page 7: ...ysteresis FE window When set to the window function the set and reset points have a fixed hysteresis of 0 25 of the final value of the measuring range This keeps the switching state of the output stab...

Page 8: ...tion location Behind the cold dryer near the load If compressed air is fed into the main pipe through parallel pipes the unit should be mounted in the main pipe Installation after the maintenance unit...

Page 9: ...wo 90 elbows two planes B 25 x pipe diameter valve slide B 45 x pipe diameter 5 3 Mounting position Permitted mounting positions pipe length vertical any position fig 1 2 pipe length horizontal unit v...

Page 10: ...egulations for the installation of electrical equipment must be adhered to Voltage supply to EN50178 SELV PELV Disconnect power Connect the unit as follows 2 switching outputs 1 switching output 1 ana...

Page 11: ...3 and 5 flashing consumed quantity before the last reset in 103 standard cubic feet LED 4 current medium temperature in F LED 6 not used LED 7 LED 8 switching state of the corresponding output 9 Alph...

Page 12: ...12 8 Menu 8 1 Menu structure Mode Enter Set scf current meter count in standard cubic feet scf stored meter count in standard cubic feet...

Page 13: ...d Analogue signal 4 20 mA SP2 rP2 Maximum minimum value for volumetric flow at which OUT2 changes its switching status ASP Analogue start value for volumetric flow AEP Analogue end value for volumetri...

Page 14: ...eter flashes for 5 s After 5 s The setting value is changed incremental by press ing briefly or scrolling by holding pressed Numerical values are incremented continuously If the value is to be reduced...

Page 15: ...alues Press Mode Enter Set for 10 s uLoc is displayed When delivered unlocked Time out If during parameter setting no pushbutton is pressed for 15 s the unit exits the param eter setting mode The para...

Page 16: ...quantity monitoring by pulse output Select OU1 and set ImP Select ImPS and set the volumetric flow quantity at which 1 pulse is provided 9 6 Select ImPR and set YES Pulse repetition is active Output...

Page 17: ...he update rate and orientation of the display d1 update of the measured values every 50 ms d2 update of the measured values every 200 ms d3 update of the measured values every 600 ms rd1 rd2 rd3 displ...

Page 18: ...e Enter briefly It makes sense to delete the memories as soon as the unit works under normal operating conditions for the first time 9 5 2 Reset all parameters to the factory setting Select rES then p...

Page 19: ...4 000 000 scf Setting operation Ensure that OU1 is set to ImP Select ImPS press Set and keep it pressed The current numerical value flashes for 5 s then one of the 4 digits becomes active digit flashe...

Page 20: ...h digit flashes unchanged for 3 s digit 1 becomes active again if the value of digit 1 is 0 8 1 2 3 no pushbutton pressed after 3 s 8 1 2 3 after 3 s 8 1 2 3 after 3 s 8 1 2 3 after 3 s 8 1 2 3 If dig...

Page 21: ...ntrols and indicating elements During the power on delay time the outputs are switched as programmed ON for NO function Hno Fno and OFF for NC function Hnc Fnc If output 2 is configured as analogue ou...

Page 22: ...es These faults are indicated even if the display is deactivated 10 4 General operating conditions The unit is maintenance free for media which will not adhere to the measuring probes From time to tim...

Page 23: ...ry setting User setting SP1 4 80 103 rP1 4 68 103 ImPS 0 400 ImPR YES OU1 Hno OU2 Hno SP2 9 60 103 rP2 9 48 103 ASP 0 00 103 AEP 24 72 103 FOU1 OFF FOU2 OFF dAP 0 6 rTo OFF diS d3 Uni SCFH SELd FLOW M...