UK
31
Output parameter OUT
Name
Data type
Description
ERROR
BOOL
0: No error
1: Error occurred, details see STATUS�
STATUS
WORD
Error code:
1� 0x0000: No error
2� 0x8000: Internal error (e�g� unexpected return value of an
SFC, undefined status word of the evaluation unit)
3� 0x8101: Evaluation unit does not exist on Profibus
4� 0x8202: Invalid parameter DIAG_DATA
The data DIAG_DATA is written with 0x00 before each execution of the
command� If there is no diagnosis, the diagnostic data reads 0x00�
Diagnosis is read via the SVD 13 "DPNRM_DG"�
Summary of Contents for efectror190 DTE100
Page 1: ...Device manual Supplement S7 library for evaluation unit DTE100 706146 00 04 2012 UK ...
Page 34: ...34 4 12 User defined data type UDT1 ETH_PARA UDT2 MAC_ADDRESS UDT3 IDENT_UNIT_PARA UDT4 CLOCK ...
Page 35: ...UK 35 UDT5 TRACEBUFFER UDT6 ANT_TYPE ...
Page 36: ...36 UDT7 BLOCK_PARA UDT8 TRANSPONDER_TYPE UDT9 IDENT_DIAG ...
Page 37: ...UK 37 UDT10 ANT_DIAG UDT11 CHANNEL_MODE UDT15 MAX_PACK_SIZE UDT16 DIAG_DATA ...
Page 38: ...38 ...