33
ifm
Device Manual Supplement: Acyclic data records and Command interface (AC14 and AC4S)
2017 / 09
Acyclic data records
>
3.18
DS18 – Fieldbus information
17038
Offset
Word no.
Bit
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
0
Fieldbus state
Fieldbus type
1
Ethernet connection status
Profibus slave address
2
Profinet/EtherNet/IP IP address / EtherCAT-Adresse
(byte 2)
Profinet/EtherNet/IP IP address / EtherCAT-Adresse
(byte 1, MSB)
3
Profinet/EtherNet/IP IP address / EtherCAT-Adresse
(byte 4, LSB)
Profinet/EtherNet/IP IP address / EtherCAT-Adresse
(byte 3)
4
Profinet/EtherNet/IP subnet mask (byte 2)
Profinet/EtherNet/IP subnet mask (byte 1, MSB)
5
Profinet/EtherNet/IP subnet mask (byte 4, LSB)
Profinet/EtherNet/IP subnet mask (byte 3)
6
Profinet/EtherNet/IP gateway address (byte 2)
Profinet/EtherNet/IP gateway address (byte 1, MSB)
7
Profinet/EtherNet/IP gateway address (byte 4, LSB)
Profinet/EtherNet/IP gateway address (byte 3)
8
MAC0 (byte 2)
MAC0 (byte 1, LSB)
9
MAC0 (byte 4)
MAC0 (byte 3)
10
MAC0 (byte 6, MSB)
MAC0 (byte 5)
11
MAC1 (byte 2)
MAC1 (byte 1, LSB)
12
MAC1 (byte 4)
MAC1 (byte 3)
13
MAC1 (byte 6, MSB)
MAC1 (byte 5)
14
MAC2 (byte 2)
MAC2 (byte 1, LSB)
15
MAC2 (byte 4)
MAC2 (byte 3)
16
MAC2 (byte 6, MSB)
MAC2 (byte 1, LSB)
17
Profinet host address (byte 2)
Profinet host address (byte 1, MSB)
18
Profinet host address (byte 4, LSB)
Profinet host address (byte 3)
Legend:
Fieldbus
type
Name of the fieldbus
1 byte
0x00 = no fieldbus present
0x01 = Profinet
0x02 = Profibus
0x03 = EtherNet/IP
0x04 = EtherCAT
Fieldbus
status
Status of the fieldbus
connection
1 byte
0x00 = initialisation
0x01 = waiting for connection
0x02 = connection is being established
0x03 = configuration of the connection in progress
0x04 = parameter setting in progress
0x05 = waiting for module configuration
0x06 = cyclic data exchange with the fieldbus controller/host
0x07 = connection release
Profibus
slave
address
Profibus address of the
device
1 byte
0x00 = no Profibus
0x03 = address 3
...
0x7B = address 123
Ethernet
connection
status
Status and Ethernet
connections on ports X6
and X7
1 byte
0x00 = no connection or Profibus
0x01 = connection on port X7 established, no connection on port X6
0x02 = connection on port X6 established, no connection on port X7
0x03 = connection on ports X6 and X7 established