2 Safety instructions

General

The unit described is a subcomponent for integration into a system.

– The system architect is responsible for the safety of the system.

– The system architect undertakes to perform a risk assessment and to create documentation in

accordance with legal and normative requirements to be provided to the operator and user of
the system. This documentation must contain all necessary information and safety instructions
for the operator, the user and, if applicable, for any service personnel authorised by the
architect of the system.

Read this document before setting up the product and keep it during the entire service life.

The product must be suitable for the corresponding applications and environmental conditions
without any restrictions.

Only use the product for its intended purpose (

Ò

 Intended use).

If the operating instructions or the technical data are not adhered to, personal injury and/or damage
to property may occur.

The manufacturer assumes no liability or warranty for any consequences caused by tampering with
the product or incorrect use by the operator.

Installation, electrical connection, set-up, operation and maintenance of the product must be
carried out by qualified personnel authorised by the machine operator.

Protect units and cables against damage.

Radio equipment

In general, radio equipment must not be used in the vicinity of petrol stations, fuel depots, chemical
plants or blasting operations.

u

Do not transport and store any flammable gases, liquids or explosive substances near the unit.

Interference of electronic and medical devices

Operation can affect the function of electronic devices that are not correctly shielded.

u

Disconnect the device in the vicinity of medical equipment.

u

Contact the manufacturer of the corresponding device in case of any interference.

Summary of Contents for ANT600

Page 1: ...Operating instructions RF identification system ANT600 Read write head 11478770 00 09 2022 GB...

Page 2: ...n 9 6 1 Notes on the unit installation 9 6 2 Avoiding interference 9 6 3 Mechanical design 9 6 4 Mounting options 9 6 4 1 Installation with angle bracket E80335 10 6 4 2 Installation with mounting dev...

Page 3: ...reference Important note Non compliance may result in malfunction or interference Information Supplementary note 1 2 Warnings used ATTENTION Warning of damage to property 1 3 Legal and copyright infor...

Page 4: ...purpose Intended use If the operating instructions or the technical data are not adhered to personal injury and or damage to property may occur The manufacturer assumes no liability or warranty for a...

Page 5: ...The read write head reads and writes ID tags without contact For use the read write head must be connected to the DTE10x evaluation unit The data is converted into digitally coded values and provided...

Page 6: ...s supplied Read write head The device is supplied without installation and connection accessories Available accessories www ifm com The optimum function is not ensured when using components from other...

Page 7: ...gy The device supports ID tags according to ISO 15693 5 2 Detection range with E80384 0 50 150 170 220 120 20 mm mm 100 200 50 100 150 200 70 1 2 3 Fig 1 Propagation field 1 Detection range at 100 HF...

Page 8: ...ANT600 8 5 3 Device overview ANT600 Article number ANT600 Function Read write head Type designation DTRHF HLRWIDUS03 Type Rectangular...

Page 9: ...ith data communication u Do not operate any devices in the vicinity that use the same frequency band w Such devices are for example frequency converters and switched mode power supplies If there are o...

Page 10: ...acket E80335 6 4 2 Installation with mounting device E80336 The mounting device is used to mount the unit on a clamp Compatible clamps E21110 with a rod diameter of 12 mm E20795 with a rod diameter of...

Page 11: ...0 6 m 0 4 m Interference in data communication is avoided if there are no other RFID UHF devices in the vicinity If there are other RFID UHF devices in the vicinity u The mounting distances between th...

Page 12: ...of the ID tags D Fig 2 Position the ID tag u Align the ID tag on the antenna central axis w The distance D is indicated in the data sheet ID tags are also detected on the back of the device To avoid t...

Page 13: ...r before connecting the device 7 1 Wiring u Connect the unit to a DTE10x evaluation unit via the M12 connector w Voltage is supplied via the evaluation unit Pin assignment Wiring 4 1 3 L 1 3 4 L DATA...

Page 14: ...shing slowly not ready for operation yellow signal bar flashing twice ID tag read written successfully flashing quickly error when reading writing on ID tag The maximum receive signal strength depends...

Page 15: ...se of malfunction u Do not open the housing as the unit does not contain any components which can be maintained by the user The unit must only be repaired by the manufacturer u Clean the device using...

Page 16: ...standards the following information is available Test standards and regulations documentation ifm com EU declaration of conformity and approvals documentation ifm com Notes relevant for approval Pack...

Page 17: ...d to identify objects A read write device is used to read the ID tag via a high frequency radio signal An ID tag consists of an antenna an analogue circuit for receiving and transmitting transceiver a...

Reviews: