ifm function elements
ifm function elements for the device CR0431
CANOPEN_GETODCHANGEDFLAG
7927
= Get object directory changed flag
Unit type = function block (FB)
Unit is contained in the library
ifm_CANopen_NT_Vxxyyzz.LIB
Symbol in CODESYS:
>
Description
7928
CANOPEN_GETODCHANGEDFLAG reports any change of value for a particular object directory
entry.
>
Parameters of the inputs
7930
Parameter
Data type
Description
EXECUTE
BOOL := FALSE
FALSE
TRUE (edge):
execute function element once
otherwise: function element is not active
A function element already started is processed.
CHANNEL
BYTE
CAN interface (1...n) depending on the device
IDX
WORD
index in object directory
SUBIDX
BYTE
sub-index referred to the index in the object directory
>
Parameters of the outputs
7931
Parameter
Data type
Description
DATA
DWORD
parameter value
RESULT
BYTE
feedback of the function block
(possible messages → following table)
Possible results for RESULT:
Value
dec | hex
Description
0
00
FB is inactive
1
01
function block execution completed without error
8
08
FB is active
– not yet processed
242
F2
Error: setting is not possible