10
5.4 Installation position
In wet environments, install the controller ensuring that no liquid remains on the
connectors�
The installation position is defined by the 90° angled cable entry� The cable entries
must be oriented vertically downwards to prevent moisture ingress� If this is not
possible then an orientation between horizontal and vertically down is allowed�
5.5 Fastening
►
Fix the controller to a flat surface using 4 zinc-plated M6 screws�
Tightening torque: 10
±2
Nm
EPS Source
Product Scale Drawing
Frame Size: 80 mm x 49,5 mm
Original Scale Drawing (MTD)
P_MZ_e100_0093
Scale: 1:2
18
47
68,4
18
47
206
219
250
271
6,4
M12x1
LEDs
1
2
Installation
Total height with the attached
connector
NOTE!
Contact corrosion between the mounting screws and the housing�
> Damage to the device
►
Do not use stainless steel screws or nickel-plated screws�
►
Use zinc-plated screws�
►
In very corrosive environments such as extremely salty air, use
screws with surface finishing on a zinc/nickel basis with thick-
film passivation and sealing�