RFID UHF reader
12
7.4 Digital inputs and outputs
The digital inputs and outputs of the DTE810/DTE910/DTE920 are designed as
two 8-pole sockets with A coding with M8 connection thread�
4
1
2
6
5
3
7
8
Pin Assignment GPIO 1
Assignment GPIO 2
1
OUT_CMN (common switching output)
OUT_CMN (common switching output)
2
INPUT 4 (switching input 4)
INPUT 1 (switching input 1)
3
INP_CMN (common switching input)
INP_CMN (common switching input)
4
GND_ext (external mass)
GND_ext (external mass)
5
+UB_ext (external operating voltage)
+UB_ext (external operating voltage)
6
OUTPUT 4 (switching output 4)
OUTPUT 2 (switching output 2)
7
OUTPUT 3 (switching output 3)
OUTPUT 1 (switching output 1)
8
INPUT 3 (switching input 3)
INPUT 2 (switching input 2)
7.4.1 Digital inputs
The inputs are electrically isolated from the operating voltage of the reader and
can be operated independently of the polarity of the input signal� For this purpose,
there is a common pole for the inputs (switching input CMN)�
Depending on the application, the inputs can be operated electrically isolated with
an external voltage or not electrically isolated with the operating voltage of the
reader�
Circuitry of the inputs electrically isolated