RFID UHF reader
14
Circuitry of the outputs not electrically isolated
Load each digital input or output with max� 0�5 A�
Load all digital inputs and outputs used with max� 1�5 A in total�
If the auxiliary voltage of the GPIO connection of the reader is used, load all
used digital inputs and outputs with all in all max� 1�1 A�
The inputs and outputs are designed for max� 30 V DC� For further
information, please refer to the data sheet�
For operation of the outputs with an external voltage source, only use
LPS (Limited Power Source) or NEC class 2 power supplies�
The control and evaluation can take place via the ReaderStart v2 software, via the
supplied DLL or by accessing the reader protocol�
7.5 Antenna connection
For connection with the RFID antennas, the reader has 4 antenna connections
which are designed as Reverse TNC�
For connection of antennas, only use the cables mentioned in the
accessories chapter (50 Ω) (→
5)!
Unsuitable cables can significantly decrease the reader's power due to
maladjustments� Maladjustments that are too significant lead to error
messages from the reader�