background image

DTI600

8

5.4 IO-Link

This unit has an IO-Link communication interface which enables direct access to process and
diagnostic data. In addition it is possible to set the parameters of the unit while it is in operation.
Operation of the unit via the IO-Link interface requires an IO-Link master.

With a PC, suitable IO-Link software and an IO-Link adapter cable, communication is possible while
the system is not in operation.

The 

IODD

 required to configure the unit is available at 

www.ifm.com

.

Summary of Contents for DTI600

Page 1: ...Operating instructions RF identification system DTI600 Read write head 11476236 00 09 2022 GB...

Page 2: ...connection 13 7 1 Wiring 13 8 Operating and display elements 14 9 Parameter setting 15 9 1 Parameter 15 9 1 1 Data block size 15 9 1 2 Data alignment 15 9 1 3 Data hold time 15 9 1 4 Address for autom...

Page 3: ...reference Important note Non compliance may result in malfunction or interference Information Supplementary note 1 2 Warnings used ATTENTION Warning of damage to property 1 3 Legal and copyright infor...

Page 4: ...purpose Intended use If the operating instructions or the technical data are not adhered to personal injury and or damage to property may occur The manufacturer assumes no liability or warranty for a...

Page 5: ...DTI600 5 3 Intended use The read write head reads and writes ID tags without contact The data is made available as process data via the IO Link interface...

Page 6: ...s supplied Read write head The device is supplied without installation and connection accessories Available accessories www ifm com The optimum function is not ensured when using components from other...

Page 7: ...e ID tag A voltage is generated by induction that supplies the data carrier with energy The device supports ID tags according to ISO 15693 5 2 Detection range with E80384 0 50 150 170 220 120 20 mm mm...

Page 8: ...is possible to set the parameters of the unit while it is in operation Operation of the unit via the IO Link interface requires an IO Link master With a PC suitable IO Link software and an IO Link ad...

Page 9: ...ith data communication u Do not operate any devices in the vicinity that use the same frequency band w Such devices are for example frequency converters and switched mode power supplies If there are o...

Page 10: ...acket E80335 6 4 2 Installation with mounting device E80336 The mounting device is used to mount the unit on a clamp Compatible clamps E21110 with a rod diameter of 12 mm E20795 with a rod diameter of...

Page 11: ...0 6 m 0 4 m Interference in data communication is avoided if there are no other RFID UHF devices in the vicinity If there are other RFID UHF devices in the vicinity u The mounting distances between th...

Page 12: ...of the ID tags D Fig 2 Position the ID tag u Align the ID tag on the antenna central axis w The distance D is indicated in the data sheet ID tags are also detected on the back of the device To avoid t...

Page 13: ...the device ATTENTION The IP rating indicated in the data sheet is only guaranteed if the M12 connectors are firmly screwed The device can be damaged by insufficiently tightened M12 connectors u Screw...

Page 14: ...K Off Operating voltage missing Flashing slowly deactivated yellow On permanently ID tag detected On pulse ID tag read written successfully Flashing quickly Error when reading writing on ID tag Off no...

Page 15: ...ent The parameter sets the order of the data in a data block of the ID tag Example For an ID tag with block size 4 bytes the data can be ordered as in the tables Data block 0 Data block 1 Byte 3 Byte...

Page 16: ...written The length is indicated in bytes The minimum length is 1 byte and the maximum length is 29 bytes In the operating modes Auto read and Auto write the device reads and writes a specified number...

Page 17: ...not acknowledged 1 Start of a read or write operation acknowledged Cmd Antenna deactivate 0 Activate antenna 1 Deactivate antenna Cmd Start 0 Reset trigger for read or write operation 1 Set trigger fo...

Page 18: ...t to each other is reduced by deactivating the antenna Deactivate the internal antenna u Set the Cmd Antenna deactivate bit in the process data output The status of the internal antenna is queried via...

Page 19: ...gth of 29 bytes the data remaining in the process image is filled with the value 0x00 The data in the process image is updated as soon as an ID tag enters the detection range The data in the process i...

Page 20: ...In the operating mode Auto write data the data to be written is defined by the process data output image The data is set with the parameters Address for Auto Read Write and Data Length for Auto Read W...

Page 21: ...6 Data 4 Data 4 7 Data 5 Data 5 8 Data 6 Data 6 9 Data 7 Data 7 10 Data 8 Data 8 11 Data 9 Data 9 12 Data 10 Data 10 13 Data 11 Data 11 14 Data 12 Data 12 15 Data 13 Data 13 16 Data 14 Data 14 17 Dat...

Page 22: ...wo steps are repeated until all data has been transferred w The device sets the status bit Cmd End with the last transfer The read operation is terminated If reading was unsuccessful the device sets t...

Page 23: ...ata 0x03 0x0012 0x0023 0x00 0x00 1 Controller ac knowledges re ceipt of the data 0x03 0x0012 0x0023 0x00 0x01 1 Device sets more data and terminates read ing 0x03 0x0012 0x0023 0x00 0x01 1 Controller...

Page 24: ...ssful Command value Address Length Data 0 to 27 Block counter Status bit Cmd Start Preset com mand 0x00 0x0000 0x0000 0x00 0x00 0 Controller sets command read 35 bytes from address 0x12 0x03 0x0012 0x...

Page 25: ...16 bits and the data length 16 bits u With the control start the write operation with the status bit Cmd Start w The device acknowledges the start of the write operation by setting the status bit Cmd...

Page 26: ...0 20 ignored Data 18 0x00 21 ignored Data 19 0x00 22 ignored Data 20 0x00 23 ignored Data 21 0x00 24 ignored Data 22 0x00 25 ignored Data 23 0x00 26 ignored Data 24 0x00 27 ignored Data 25 0x00 28 ign...

Page 27: ...tus bit Cmd End Status bit Cmd Start Preset com mand 0x00 UID 0x00 0x00 0 0 Controller sets command write 40 bytes to ad dress 0x10 0x04 UID 0x00 0x00 0 0 Device acknowl edges com mand 0x04 0x00 0x00...

Page 28: ...2 1 Controller with draws com mand value 0x00 0x0000 0x0000 0x00 0x00 0 Device carries out preset com mand 0x00 0x0000 0x0000 0x00 0x00 0 Tab 9 Process data output Command value Data 0 to 27 Block cou...

Page 29: ...reception of the data of the ID tag 0x21 TAG_COMMAND_NOT_SPECIFIED Command is not supported by the ID tag 0x22 TAG_COMMAND_SYNTAX Parameter of the command wrong 0x23 TAG_OPTION_NOT_SUPPORTED ID tag d...

Page 30: ...ase of malfunction u Do not open the housing as the unit does not contain any components which can be maintained by the user The unit must only be repaired by the manufacturer u Clean the device using...

Page 31: ...standards the following information is available Test standards and regulations documentation ifm com EU declaration of conformity and approvals documentation ifm com Notes relevant for approval Pack...

Page 32: ...volatile memory IODD Digital description of the device The IODD is required for device parameter setting via IO Link IO Link IO Link is a standardised IO technology IEC 61131 9 for communicating with...

Reviews: