3
UK
Scale drawing
4
58
1 m
1 m
Technical data
5
Input voltage [V]..................................................................................................... 9...27 DC
Current consumption max. [mA] ..................................................................................... 500
Sensor supply
Supply voltage [V] .................................................................................................... 24 DC
Operating current max. [mA] ......................................................................................... 125
Materials .................................................................................................... housing: PBT GF
cable: PUR; connector housing: TPU orange;
sealing: Viton; nut: brass nickel-plated
Protection ................................................................................................................ IP 40, III
Ambient temperature [°C] ....................................................................................... -25...70
EMC EN 61000-4-2 ESD: ..................................................................................... 4 / 15 kV
EN 61000-4-3 HF radiated: ................................................. 30 V/m (80...1000 MHz)
EN 61000-4-4 Burst: .................................................................. 2 kV coupling clamp
EN 61000-4-6 HF conducted: .................................................. 10 V (0.15...80 MHz)
Further information at
www.ifm.com
→
Select your country
→