page 111
Function
TIMER_US_READ
Library
CRxxxx.LIB
Function symbol
Parameter
The current system time is read in
µ
seconds.
Parameter
Function inputs, none
Function output
Description
When the supply voltage is applied a time cycle is generated in
the unit and is counted up in a register. This register can be
read by means of the function call and can be used e.g. for
measuring time.
The system timer runs up to a max. value of 4294967295 (
µ
s)
and then starts again at 0.
Name
Data type Description
TIME_US
DWORD
Current system time in
µ
seconds