page 97
8.
Fast counters in the ecomat R 360
The controller ecomat R 360 has a total of 8 fast inputs which
can process input frequencies up to 50 kHz. Apart from
measuring the frequency at the inputs FRQ0...FRQ3 the inputs
ENC0 to ENC3 can also be used to evaluate encoders (counter
functions) with a maximum frequency of 10 kHz.
The functions FREQUENCY and INC_ENCODER are available
for simple evaluation.
If the fast inputs of the ecomat R 360 are used as "normal"
digital inputs the increased sensitivity to noise has to be
taken into account (e.g. contact bouncing in the case of
mechanical contacts). The standard digital input has an
input frequency of 50 Hz. If required, the input signal has
to be debounced by means of the software.
Input
Frequency
Description
FRQ 0/ENC 0
50 /10 kHz
frequency measurement / channel A,
encoder 1
FRQ 1/ENC 0
50 /10 kHz
frequency measurement / channel B,
encoder 1
FRQ 2/ENC 1
50 /10 kHz
frequency measurement / channel A,
encoder 2
FRQ 3/ENC 1
50 /10 kHz
frequency measurement / channel B,
encoder 2
ENC 2
10 kHz
channel A, encoder 3
ENC 2
10 kHz
channel B, encoder 3
ENC 3
10 kHz
channel A, encoder 4
ENC 3
10 kHz
channel B, encoder 4
Summary of Contents for ecomat 100 R 360 Series
Page 1: ...System manual ecomat 100 type R 360 ...
Page 14: ...page 14 ...
Page 26: ...page 26 ...
Page 86: ...page 86 ...
Page 100: ...page 100 ...
Page 126: ...page 126 ...
Page 146: ...page 146 ...
Page 162: ...page 162 ...
Page 163: ...page 163 Annex 2 Wiring Annex 2 1 Type CR0015 ...
Page 164: ...page 164 Annex 2 2 Type CR0016 ...
Page 165: ...page 165 Annex 2 3 Type CR0017 ...
Page 166: ...page 166 Annex 2 4 Type CR0501 ...