Function and features
The preset counter evaluates the input pulses, processes them according
to the programmed functions and displays the result in two 6-digit
displays and switches the output relay depending on the programmed
output performance.
• Counts pulses from incremental shaft encoders, mechanical or
electronic pulse pick-ups.
• Supply of the pulse pick-ups via integrated power supply.
• Programming possibilities for pulse processing and display.
• Preprogrammed basic setting.
• Preset.
Operation and display elements
Mounting
There are two brackets with threaded holes at the back of the unit.
Mount the counter in your plant using the screws supplied; panel
cut-out: 67mm x 92mm.
P
Reset
Out 1
= incrementing in active decade
= changing to next decade
selection of parameter address;
setting of parameter value
actual value display
preset display
LED;
is lit when the relay is energised
front reset
change into programming mode;
acknowledgement of parameter
address and parameter value