ifm
Device manual AS-i M4 Gateway Profibus DPV1 (AC1375, AC1376)
2012-02-23
Set-up
Configuration of the slaves
119
9 Set-up
Configuration of the slaves........................................................................................................ 119
Change slave parameter data................................................................................................... 133
Password protection.................................................................................................................. 136
Reset to factory preset .............................................................................................................. 140
Update firmware ........................................................................................................................ 142
Character sets ........................................................................................................................... 142
Set the parameters of the fieldbus interface in the device........................................................ 143
Parameter setting of the Profibus host...................................................................................... 145
5495
This chapter shows you how to get the device started quickly.
After power-on the display (
→
What is what in the text/graphics display? (
→
)) shows a start
screen and possibly an error message of the connected AS-i system.
9.1
Configuration of the slaves
Permissible slave addresses..................................................................................................... 120
Automatic individual addressing of slaves ................................................................................ 121
Manual slave addressing .......................................................................................................... 124
Finish configuration ................................................................................................................... 128
Enter detected slaves in the configuration list........................................................................... 131
5197
In this chapter you will learn about the methods how to address slaves using this device.
NOTE
Every address is allowed in the system only once so that the AS-i master can communicate with every
slave individually.
Slaves with the address 0 do not operate on the bus.
The manufacturers of AS-i slaves always deliver their devices with the address 0.
> If address is wrong or has been assigned twice:
The device displays an error message and does not process the slaves.