Troubleshooting
Online Support Center (OSC)
>
7.3.1
OSC: View current error messages
15842
The [Current] tab lists all current messages. The messages are in chronological order. All messages
regarding warnings and errors are displayd.
Information about the different types of messages:
→
Message types
(
Overview of possible OSC messages of the device:
→
OSC messages
(
To view the error messages that are currently active:
1 Select the menu page
►
►
Select [Current] tab.
2 Show current messages
>
The page shows the error messages that are currently active.
►
Press [
] to select the message field.
>
The focus (orange frame) is on the message field.
►
Use [
]/[
] to go through the error messages.
3 Optional: filter messages
►
Set the following parameters as required:
Parameter
Meaning
Possible values
[Filter]
System component the
message was created in
All
=
Display all messages in chronological
order of their occurrence (= preset).
AS-i 1
=
Display messages that were created in
AS-i master 1.
AS-i 2
=
Display messages that were created in
AS-i master 2 (only selectable for
devices with 2 AS-i masters).
System
=
Display messages that were created in
the system.
>
Page shows filtered messages.