background image

Operating instructions 

Diffuse reflection sensor with  

background suppression

O4H5xx  

706276 / 00

 

11 / 2012

UK

Summary of Contents for efector 200 O4H5 Series

Page 1: ...Operating instructions Diffuse reflection sensor with background suppression O4H5xx 706276 00 11 2012 UK ...

Page 2: ...ult in malfunctions or interference 2 Functions and features The diffuse reflection sensor detects objects and materials without contact and indicates their presence by a switching signal Range type label Align the diffuse reflection sensor to the object to be detected Secure it to a bracket 3 Operating and display elements 1 2 3 1 LED 2 OUT on button 3 OUT off button ...

Page 3: ...teed 4 Electrical connection The unit must be connected by a qualified electrician The national and international regulations for the installation of electrical equipment must be adhered to Ensure voltage supply to EN 50178 Disconnect power Connect the unit as follows Connector pin 1 L pin 2 not connected pin 3 L pin 4 load Cable BN L BU L BK load Core colours BN brown BU blue BK black ...

Page 4: ...tected Position the object see figure 1 and press OUT off Remove the object see figure 2 and press OUT on The settings can also be carried out first without object and then with object 5 2 Setting of maximum sensitivity Align the sensor so that no light is reflected The sensor is to switch when the object is detected First press OUT on then OUT off The sensor is to switch when the object is not de...

Page 5: ...e of the LED status To unlock repeat this step 6 Operation Check whether the unit operates correctly Display by LEDs 7 Maintenance repair disposal Keep the lens of the sensor free from soiling For cleaning do not use any solvents or cleaning agents which could damage the plastic parts After use dispose of the unit in an environmentally friendly way in accordance with the applicable national regula...