2 Safety instructions

2.1. General

These instructions are part of the device . It contains information and illustrations 

about the correct handling of the device and must be read before installation or 

use
Observe the operating instructions . Non-observance of the instructions, operation 

which is not in accordance with use as prescribed below, wrong installation or 

incorrect handling can seriously affect the safety of people and machinery .

2.2 Target group

These instructions are intended for authorised persons according to the EMC and 

low-voltage directives . The device must only be installed, connected and put into 

operation by a qualified electrician .

2.3 Electrical connection

Disconnect the device externally before handling it . If necessary, also disconnect 

any independently supplied output load circuits .
If the device is not supplied by the mobile on-board system (12/24 V battery 

operation), it must be ensured that the external voltage is generated and supplied 

according to the criteria for safety extra-low voltage (SELV) as this voltage is 

supplied without further measures to the connected controller, the sensors and the 

actuators .
The wiring of all signals in connection with the SELV circuit of the device must also 

comply with the SELV criteria (safety extra-low voltage, safe electrical separation 

from other electric circuits) .
If the supplied SELV voltage is externally grounded (SELV becomes PELV), the 

responsibility lies with the user and the respective national installation regulations 

must be complied with . All statements in this document refer to the device the 

SELV voltage of which is not grounded .
The connection terminals may only be supplied with the signals indicated in the 

technical data and/or on the device label and only the approved accessories of ifm 

electronic gmbh may be connected .

2.4 Tampering with the unit

In case of malfunctions or uncertainties please contact the manufacturer . 

Tampering with the unit can seriously affect the safety of operators and machinery . 

It is not permitted and leads to the exclusion of any liability and warranty claims .

Summary of Contents for Efector 250 O2M113

Page 1: ...Device manual Ethernet camera for mobile applications O2M113 7390810 00 03 2012 UK ...

Page 2: ...play 11 7 Set up 12 7 1 IP addresses 12 7 2 IP address allocation cameras 12 7 2 1 Checking the IP address 17 8 Technical data 18 9 Maintenance repair and disposal 19 10 Approvals standards 19 Licences and trademarks Microsoft Windows Windows XP and Windows Vista are registered trademarks of Microsoft Corporation All trademarks and company names are subject to the copyright of the respective compa...

Page 3: ...Cross reference Important note Non compliance can result in malfunctions or interference Information Supplementary note 1 2 Warning signs used WARNING Warning of serious personal injury Death or serious irreversible injuries may result CAUTION Warning of personal injury Slight reversible injuries may result NOTE Warning of damage to property ...

Page 4: ...ernal voltage is generated and supplied according to the criteria for safety extra low voltage SELV as this voltage is supplied without further measures to the connected controller the sensors and the actuators The wiring of all signals in connection with the SELV circuit of the device must also comply with the SELV criteria safety extra low voltage safe electrical separation from other electric c...

Page 5: ...g Protection rating IP 69K Regulated lens heating can be deactivated CMOS image sensor resolution VGA 320 x 240 pixels Angle of aperture 115 Operation display via integrated LED 4 Mounting 4 1 Mounting accessories The device is supplied without mounting accessories Depending on the intended location and type of mounting the following mounting accessories are available Mounting accessories examples...

Page 6: ...distance operating distance and field of view size 1 operating distance m 2 width of field of view m 3 height of field of view m To avoid adverse effects on the image detection avoid installation in heavily polluting areas of the machine e g splashing water tyre abrasion etc Avoid back light Do not position lighting elements directly facing the camera lens Mount the device in such a way that the c...

Page 7: ...lded CAT5 cable STP Shielded Twisted Pair according to EIA TIA 568 Max length 100 m Use screened connector housings Connect the screen of the Ethernet cable to the connector housing Avoid transmission problems caused by induction Do not lay the Ethernet connection cable in parallel to current carrying cables Lay supply and signal cables away from the camera using the shortest possible route 5 1 2 ...

Page 8: ...IP address Ethernet interface 8 pole RJ45 connector 1 8 1 2 3 6 TxD TxD RxD RxD Pair 1 Pair 2 The IP address range Net ID of the PC must correspond to the IP address range of the camera For the PC notebook the setting is carried out in the Control Panel Network Connections Properties also see 7 2 IP address allocation Ethernet cameras ...

Page 9: ...ay or at a PC notebook e g service mode Crosslink cable crossover cable for the direct connection of network participants Crosslink cable principle Cross link cable example Art no Ethernet connection cable 2 m M12 connector 4 poles D coded RJ45 8 poles E11898 For further information about the connector go to www ifm com Data sheet direct E11898 ...

Page 10: ...th hub switch Several cameras at one display Patch cable uncrossed cable 1 1 wiring straight through cable point to point Patch cable principle Adhere to the documentation of the switch manufacturer Some switches have an autocrossing function The transmit and receive wires are automatically recognised by these devices In this case 1 1 patch cables are not compulsory ...

Page 11: ...UK Ethernet camera O2M113 11 6 Operation display LED green 1 Status Description ON supply voltage ok camera ready for operation OFF no supply voltage power supply interrupted Operation display O2M113 ...

Page 12: ...several cameras set the IP addresses of the cameras via the Hypertext Transfer Protocol HTTP To do so use standard programs such as Microsoft Internet Explorer Mozilla Firefox or Opera 1 Display Ethernet Cameras Hub Switch 2 3 4 IP address allocation when using 4 cameras example Ethernet camera 1 Ethernet camera 2 Ethernet camera 3 Ethernet camera 4 Display 192 168 82 15 factory setting 192 168 82...

Page 13: ...Ethernet connection between the camera and the PC notebook Connect the camera to supply voltage Do not interrupt the supply voltage during IP address allocation Avoid voltage fluctuations during IP address allocation Open the internet browser Enter the preset IP address of the camera in the address line of the browser and confirm with Enter http 192 168 82 15 In the browser appears the O2M1xxx Web...

Page 14: ...he new address in the field IP address and click on Submit to send it to the camera 192 168 82 16 192 168 82 201 http 192 168 82 15 O2M1xx IP configuration The factory settings in Netmask Gateway and Force Ethernet Speed can be adopted ...

Page 15: ...Ethernet camera O2M113 15 A confirmation appears if the address was successfully written to the flash memory of the camera 192 168 82 16 192 168 82 201 http 192 168 82 15 Confirmation of the address change ...

Page 16: ...tried to send an invalid address to the camera 192 168 2 16 192 168 82 201 http 192 168 82 15 Error message in case of invalid IP address e g wrong address range In case of an error message correct the entered IP address and send it again to the camera with Submit ...

Page 17: ...er the new IP address of the camera in the address line of the browser and confirm with Enter here e g http 192 168 82 16 http 192 168 82 16 Reboot request to check the allocated IP address If the address corresponds to the previously allocated address the O2M1xxx WebConfig start window appears again The new camera IP address will become effective on reboot camera supply voltage off on Repeat chap...

Page 18: ...ign Operating distance m Field of view size m Operating voltage V Power consumption W Lens heating W Type of sensor Image repetition rate Hz Protocol Data format Readiness for operation LED Operating temperature C Storage temperature C Protection Standards tests Materials Interface Transmission rate IP address default Wiring Control systems ifm electronic gmbh Friedrichstraße 1 45128 Essen We rese...

Page 19: ...ndow do not use any detergents or solvents which might damage the front glass Do not open the housing as the device does not contain any components which must be maintained by the user The device must only be repaired by the manufacturer Dispose of the device in accordance with the national environmental regulations 10 Approvals standards Test standards and regulations 8 Technical data ...

Reviews: